DISCONTINUED

User-Friendly Interface

Configuration: Stereo. 

Impedance: >10kΩ load impedance, electronically balanced

Nominal Input Level: Software adjustable from –9.0 to +13.0 dBu (VU). 

Connectors: Two XLR-type, female, EMI-suppressed. Pin 1 chassis ground, Pins 2 (+) and 3 electronically balanced, floating and symmetrical.
 
A/D Conversion: 24 bit 128x oversampled delta sigma converter with linear-phase anti- aliasing filter. Converter outputs 64 kHz sample rate, which the 5500i then decimates to 32 kHz in DSP using an ultra-high-quality image-free synchronous sample rate converter. In strand-alone stereo encoder mode, 64 kHz output of converter is not down- sampled. 

Filtering: RFI filtered.
 

Analog Audio Output

Configuration: Stereo. Flat or pre-emphasized (at 50μs or 75μs), software-selectable. 

Source Impedance: 50Ω, electronically balanced and floating.

Load Impedance: 600Ω or greater, balanced or unbalanced. Termination not required or recommended. 

Output Level (100% peak modulation): Adjustable from –6 dBu to +24 dBu peak, into 600Ω or greater load, software-adjustable.

Signal-to-Noise: >= 90 dB unweighted (Bypass mode, de-emphasized, 20 Hz–15 kHz bandwidth, referenced to 100% modulation). 

L/R Crosstalk: <= –70 dB, 20 Hz–15 kHz. 

Distortion: <= 0.01% THD (Bypass mode, de-emphasized) 20 Hz–15 kHz bandwidth. 

Connectors: Two XLR-type, male, EMI-suppressed. Pin 1 chassis ground, Pins 2 (+) and 3 electronically balanced, floating and symmetrical. 

D/A Conversion: 24 bit 128x oversampled, with high-pass filter at 0.15 Hz (–3 dB). 

Filtering: RFI filtered. 
 

Digital Audio Input

Configuration: Stereo per AES3 standard, 24 bit resolution, software selection of stereo, mono from left, mono from right or mono from sum. 

Sampling Rate: 32, 44.1, 48, 88.2, or 96 kHz, automatically selected.

Connector: XLR-type, female, EMI-suppressed. Pin 1 chassis ground, pins 2 and 3 transformer balanced and floating, 110Ω impedance.

Input Reference Level: Variable within the range of –30 dBFS to –10 dBFS.

J.17 De-emphasis: Software-selectable.

Filtering: RFI filtered. 
 

Digital Audio Output

Configuration: Stereo per AES3 standard. Output configured in software as flat or pre- emphasized to the chosen processing pre-emphasis (50μs or 75μs), with or without J.17 pre-emphasis. 

Sample Rate: Internal free running at 32, 44.1, 48, 88.2 or 96 kHz, selected in software. Can also be synced to the AES3 digital input at 32, 44.1, 48, 88.2 or 96 kHz, as configured in software. 

Word Length: Software selected for 24, 20, 18, 16 or 14-bit resolution. First-order high-pass noise-shaped dither can be optionally added, dither level automatically adjusted appropriately for the word length. 

Connector: XLR-type, male, EMI-suppressed. Pin 1 chassis ground, pins 2 and 3 trans- former balanced and floating, 110Ω impedance. 

Output Level (100% peak modulation): –20.0 to 0.0 dBFS software controlled. Filtering: RFI filtered. 
 

Wordclock/10 MHz Sync Reference Input

Configuration: Accepts 1 x wordclock or 10 MHz reference signals, automatically selected. The DSP master clock can be phase-locked to these signals, which in turn phase-locks the 19 kHz pilot tone frequency, facilitating singe-frequency network operation. The digital output sample frequency can also be locked to these signals. 

Level: Unit will lock to 1 x wordclock and 10 MHz squarewaves and sinewaves having a peak value of 0.5 V to 5.0 V. 

Connector: BNC female, grounded to chassis, non-terminating to allow reference signals to be looped through via an external BNC “tee” connector (not supplied).
 

Composite Baseband Output

Configuration: Two outputs, each with an independent software-controlled output level control, output amplifier and connector.

Source Impedance: 0Ω voltage source or 75Ω, jumper-selectable.

Load Impedance: 37Ω or greater. Termination not required or recommended. 

Maximum Output Level: +16.0 dBu (13.82Vp-p). 

Pilot Level: Adjustable from 6.0% to 12.0%, software controlled. 

Pilot Stability: 19 kHz, ±1.0 Hz (10 degrees to 40 degrees C). 

D/A Conversion: 24-bit

Signal-to-Noise Ratio: >= 85 dB (Bypass mode, de-emphasized, 20 Hz – 15 kHz band- width, referenced to 100% modulation, unweighted). 

Distortion: <= 0.02% THD (Bypass mode, de-emphasized, 20 Hz – 15 kHz bandwidth, referenced to 100% modulation, unweighted). 

Stereo Separation: > 50 dB, 30 Hz - 15 kHz. 60 dB typical at 400 Hz.

Crosstalk-Linear: <= –80 dB, main channel to sub-channel or sub-channel to main channel (referenced to 100% modulation). 

Crosstalk-Non-Linear: <= –80 dB, main channel to sub-channel or sub-channel to main channel (referenced to 100% modulation). 

38 kHz Suppression: >= 70 dB (referenced to 100% modulation). 

76 kHz & Sideband Suppression: >= 80 dB (referenced to 100% modulation). 

Pilot Protection: 60 dB relative to 9% pilot injection, ±250 Hz (up to 2 dB composite processing drive).

Subcarrier Protection (60-100 kHz): >= 70 dB (referenced to 100% modulation; with up to 2 dB composite limiting drive; measured with 800 line FFT analyzer using “maximum peak hold” display). 

57 kHz (RDS/RBDS) Protection: 50 dB relative to 4% subcarrier injection, ±2.0 kHz (up to 2 dB composite processing drive). 

Connectors: Two BNC, shell connected to chassis ground, EMI suppressed.

Maximum Load Capacitance: 0.047 microfarad (0Ω source impedance). Maximum cable length of 100 feet/30 meters RG–58A/U. Filtering: RFI filtered.
 

Subcarrier (SCA) Inputs

Configuration: Two subcarrier inputs sum directly into composite baseband outputs; COMPx LVL control settings have no effect on the absolute subcarrier levels. 

Impedance: 600Ω 

SCA Sensitivity: Variable from <100 mV p-p to >10 V p-p to produce 10% injection assuming 100% modulation = 4 V p-p at the 5500’s composite outputs. Rear-panel accessible PC-board-mounted trim pots allow user to adjust the sensitivities of the two SCA inputs. 

Connectors: Two BNC, shell connected to chassis ground, EMI suppressed.

19 kHz Pilot Reference: SCA2 input can be re-jumpered to provide a 19 kHz pilot reference output.
 

Remote Computer Interface

Supported Computer and Operating System: IBM-compatible PC running Microsoft Windows® 2000 (SP3 or higher) or XP, ME vista 7, and 8, 8.1 and 10

Configuration: TCP/IP protocol via direct cable connect, modem, or Ethernet interface. Suitable null modem cable for direct connect is supplied. Modem and other external equipment is not supplied. 

Serial Connector:> RS–232 on DB–9 male connector, EMI-suppressed. Uses PPP to pro- vide for direct or modem connection to the 5500i PC Remote application. 

Ethernet Connector: Female RJ45 connector for 10-1000 Mbps networks using CAT5 cabling. Native rate is 100 Mbps. Provides for connection to the 5500i PC Remote application through either a network, or, using a crossover Ethernet cable, directly to a computer. 

Ethernet Networking Standard: TCP/IP.
 

Remote Control (GPI) Interface

Configuration: Eight (8) inputs, opto-isolated and floating.

Voltage: 6–15V AC or DC, momentary or continuous. +12VDC provided to facilitate use with contact closure.

Connector: DB–25 male, EMI-suppressed. 

Control: User-programmable for any eight of user presets, factory presets, bypass, test tone, stereo or mono modes, analog input, digital input.
 

Tally Outputs

Circuit Configuration: Two NPN open-collector outputs.

Voltage: +15 volts maximum. Do not apply negative voltage. When driving a relay or other inductive load, connect a diode in reverse polarity across the relay coil to protect the driver transistors from reverse voltage caused by inductive kickback. 

Current: 30 mA maximum

Indications: Tally outputs can be programmed to indicate a number of different operational and fault conditions, including Input: Analog, Input: Digital, Analog Input Silent, AES Input Silent, and AES Input Error.
 

Power

Voltage: 85–264 VAC, 50–60 Hz, 30 VA.

Connector: IEC, EMI-suppressed. Detachable 3-wire power cord supplied.

Fuse:> 2.5A 20mm Quick Acting HBC, mounted on the power supply circuit board.

Grounding: In order to meet EMI standards, circuit ground is hard-wired to chassis ground. 

Safety Standards: ETL listed to UL standards, CE marked.
 

Environmental

Operating Temperature: 32° to 122° F / 0° to 50° C for all operating voltage ranges.
 
Humidity: 0–95% RH, non-condensing. 

Dimensions (W x H x D): 19” x 1.75” x 14.25” / 48.3 cm x 4.5 cm x 36.2 cm. One rack unit high. 

Humidity: 0–95% RH, non-condensing.

RFI/EMI: Tested according to Cenelec procedures. FCC Part 15 Class A device. 

Shipping Weight & Dimensions: 18 lbs / 8.2 kg - 23" x 23" x 6"
 

Warranty

Five Years, Parts and Service: Subject to the limitations set forth in Orban's Standard Warranty Agreement.

Because engineering improvements are ongoing, specifications are subject to change without notice.